Back to Problem & Solution
Material Analysis 9 views

Dichloromethane test of PVC pipe

Problem Phenomenon
Dichloromethane immersion test fails
Cause Analysis
Insufficient plasticization degree, not fully gelled
Solution
Increase the processing temperature to ensure the plasticization degree
Key Takeaway
Dichloromethane test is an indicator of plasticization degree