Material Analysis
9 views
Dichloromethane test of PVC pipe
Problem Phenomenon
Dichloromethane immersion test fails
Cause Analysis
Insufficient plasticization degree, not fully gelled
Solution
Increase the processing temperature to ensure the plasticization degree
Key Takeaway
Dichloromethane test is an indicator of plasticization degree
Was this helpful?
0 people found this helpful