Molds & Tooling 2 views

Poor surface gloss of EAA

Problem Phenomenon
The surface gloss of EAA products is <60%, below the 80% requirement, dull appearance
Cause Analysis
Mold surface rough Ra>0.4μm; EAA crystallinity high, surface microcrystals scatter light; improper cooling rate
Solution
1) Polish the mold to a mirror finish of Ra<0.1μm; 2) Raise the mold temperature to delay crystallization and reduce scattering; 3) Add a nucleating agent to control the crystal size
Key Takeaway
Poor gloss is caused by mold roughness and crystallization scattering; polishing the mold and controlling crystallization are the key
EAA gloss mold polishing crystallization scattering nucleating agent