Molds & Tooling
2 views
PU length out of tolerance
Problem Phenomenon
PU product length deviation >±0.5mm, out of tolerance
Cause Analysis
PU shrinkage unstable, fluctuating ±0.5%; mold dimension design did not consider shrinkage compensation; insufficient cooling, dimensions not stabilized
Solution
1) Precisely measure PU shrinkage and compensate the mold; 2) Fully cool to ensure dimensional stability; 3) Annealing treatment to eliminate post-shrinkage
Key Takeaway
Length out of tolerance is caused by unstable shrinkage; precise shrinkage compensation is key
Was this helpful?
0 people found this helpful