Analysis and resolution of SiO₂ particle size of Anti-block MB in pearlized film labels
Problem Phenomenon
When producing labels with pearlized film, Anti-block MB exhibits abnormal performance related to SiO₂ particle size.
Cause Analysis
The main cause is that parameters related to SiO₂ particle size fluctuate excessively, leading to unstable processing.
Solution
Comprehensively solve the SiO₂ particle size problem from the perspective of process adjustment.
Key Takeaway
The control of SiO₂ particle size of Anti-block MB is a key link in ensuring processing quality.