2 views
LCP hot runner system challenge
Problem Phenomenon
LCP hot runners need to operate stably at 380-400°C ultra-high temperature for long periods.
Cause Analysis
Conventional hot runner seals and heaters cannot meet the stringent ultra-high temperature requirements.
Solution
Use ultra-high temperature grade hot runner systems (high-temperature alloy seals).
Key Takeaway
LCP hot runners are an extreme working condition challenge.