Menu
Materials Machinery
Insights
Articles Videos Problem & Solution
About
About Chembull Media Partners
Contact Us
Language
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Back to Problem & Solution
Extrusion & Post 1 views

POE extrusion melt fracture

Problem Phenomenon
When the POE extrusion rate is too high, severe melt fracture occurs, and the extrudate shows spiral distortion
Cause Analysis
POE melt elasticity too high, elastic recovery at the die exit exceeds the critical value; die L/D ratio too short <10, melt not fully relaxed; extrusion temperature too low
Solution
1) Reduce extrusion rate to 2-3m/min; 2) Increase die L/D ratio to 15-20; 3) Increase extrusion temperature to 160-200°C; 4) Add a small amount of low-elasticity resin to reduce system elasticity; 5) Progressive converging die entrance design
Key Takeaway
Melt fracture is caused by elastic recovery exceeding the critical value; reducing speed and lengthening the die are the core countermeasures
POE extrusionmelt fractureelastic recoverydie L/Dextrusion rate

Was this helpful?

0 people found this helpful

ChemAI