Sticking to Mold of PCTG Injection Molded Products

Problem Phenomenon
PCTG products are difficult to demold and stick to the mold surface.
Cause Analysis
PCTG melt has strong adhesion to metal, the demolding draft is insufficient, and the mold surface has no release coating.
Solution
Increase the demolding draft ≥2°; use chrome-plated or DLC coated molds; appropriately reduce the mold temperature.
Key Takeaway
PCTG mold sticking requires mold surface treatment and demolding design.
PCTGmold stickingdemoldingcoatingdemolding draft