Molds & Tooling
2 views
Improper mold steel selection for PCTG
Problem Phenomenon
Improper mold steel surface damaged during use.
Cause Analysis
Mold steel not resistant to PCTG processing temperature and additive erosion.
Solution
Select stainless mold steel suitable for PCTG (such as S136H, etc.).
Key Takeaway
PCTG mold life is related to steel.
Was this helpful?
0 people found this helpful