Mold seal aging

Fenómeno do problema
Seal failure causes material leakage. When this defect occurs in products of Process No. 2, it is usually related to a specific process parameter range or equipment status. If it persists, it will directly affect the product qualification rate and production cycle, increasing material loss and rework costs. Timely diagnosis and elimination is a basic requirement to ensure stable production.
Análise das causas
1. Material factor: The reaction material corrodes the seals, high-temperature aging, long-term compression deformation, and incompatible seal material. 2. Mixing quality factor: In the RIM process, the mixing uniformity of the two components is the foundation of all quality; the Reynolds number of the mixing head, the impingement mixing energy, and the residence time distribution are the key engineering parameters that determine the mixing quality. 3. Temperature control factor: The raw material temperature affects the component viscosity and reaction rate, and the mold temperature affects the curing process and product surface quality; both need to be precisely controlled within a narrow window.
Solução
1. Process parameter optimization and adjustment: Select seal materials resistant to chemical corrosion and high temperature, regularly replace the seals, and optimize the seal structure design. 2. Systematic troubleshooting method: RIM problem troubleshooting follows the order of "formulation -> mixing -> temperature control -> equipment". First check the two-component ratio and catalyst dosage, then check the mixing head and self-cleaning function, next troubleshoot the raw material and mold temperature control, and finally check the accuracy of the metering pump and hydraulic system. 3. Preventive management: Establish standardized process parameter cards and quality control limits for each mold/product, and regularly conduct process capability index (CPK) assessments. For recurring problems, use fishbone diagrams or 5Why analysis to trace the root cause, and solidify countermeasures as PFMEA control points.
Conclusão principal
This problem is a typical manifestation of mold seal aging in the RIM process, and the core of the solution lies in ensuring the precise ratio and sufficient mixing of the two components, while controlling the reaction temperature and curing conditions within the optimal window. It is recommended to start troubleshooting from the mixing system and metering accuracy.