Extrusion & Post 8 visualizações

ABAK spray coating solvent resistance

Fenómeno do problema
Insufficient solvent resistance after ABAK spray coating; the coating attacks the substrate.
Análise das causas
There is little research on ABAK spray coating solvent resistance; solvents attack the alloy; compatibility of coating and substrate; internal stress cracking; surface pretreatment.;during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience
Solução
①Solvent-resistant coating selection; ②substrate pretreatment; ③stress management; ④compatibility testing; ⑤process verification.;after adjustment, continuously sample to verify the effect, and resume mass production after confirming stability
Conclusão principal
ABAK spray coating solvent resistance is an application detail; matching of coating and substrate; testing ensures long-term quality.;after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
ABAK;spray coating;solvent resistance;coating;compatibility;pretreatment