Material Analysis 6 visualizações

COC Bottle Cap Seal Failure

Fenómeno do problema
The sealing test of the COC medicine bottle and bottle cap fit leaks, the torque retention decays over time, and the shelf-life seal integrity is unqualified.
Análise das causas
Internal stress relaxation of COC products causes slight changes in the thread fit dimensions; creep characteristics cause the compression force to decay over time; unstable molding shrinkage control causes fit tolerance drift.
Solução
①Mold with low stress and fully set to reduce relaxation; ②consider creep compensation in the seal structure design; ③shelf-life verification of dimensions and sealability; ④fix the fit tolerance according to the measured shrinkage.
Conclusão principal
The long-term performance of COC seals is governed by creep and stress relaxation; shelf-life verification is a compulsory question for pharmaceutical packaging materials; structural compensation is more economical than material replacement.; After confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence