Processing Machinery 7 visualizações

LCP Product Inspection Standard

Fenómeno do problema
Dimensional inspection disputes.
Análise das causas
LCP anisotropy makes single-direction inspection insufficient; supplier and buyer have different understandings of inspection methods.; during on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based solely on experience
Solução
①Clarify full-direction inspection requirements; ②agree on inspection benchmarks; ③first article full-dimension report; ④standard sample confirmation.; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Conclusão principal
LCP inspection must cover anisotropy characteristics; full-direction verification is standard practice.; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence