Material Drying
7 visualizações
LCP Product Drying Equipment
Fenómeno do problema
Drying effect verification.
Análise das causas
LCP drying target of 0.01% is extremely strict; ordinary equipment can hardly meet the standard.; during on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based solely on experience; this mechanism has been repeatedly verified by industry data and should be confirmed first during troubleshooting
Solução
①High-efficiency dehumidifying dryer; ②dew point ≤-40℃; ③moisture content testing verification; ④regularly calibrate equipment.; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Conclusão principal
LCP drying equipment requires high-standard configuration; testing verification is indispensable.; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a reference for troubleshooting similar problems in the future
Isto foi útil?
0 pessoas acharam isto útil