Molds & Tooling
7 visualizações
Low LCP Weld Strength Constrains Structural Design
Fenómeno do problema
【Problem Phenomenon】LCP structural parts with holes or multiple gates have weld strength far lower than the body and cannot withstand assembly torque
Análise das causas
LCP's self-reinforcing oriented structure makes molecular entanglement at the weld interface extremely low, so weld strength is inherently low; South China University of Technology literature lists low weld strength as one of LCP's main disadvantages
Solução
For hole positions, use core-pulling followed by machining instead of melt flow-around; change multiple gates to a single gate to eliminate weld lines; locally thicken stressed weld areas and add reinforcing ribs, or use insert connections instead
Conclusão principal
Low weld strength is LCP's nature; eliminating or avoiding weld lines in design is the right way; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
Isto foi útil?
0 pessoas acharam isto útil