Processing Machinery 6 visualizações

PA12 Product Low-Temperature Toughness

Fenómeno do problema
Low-temperature application verification.
Análise das causas
PA12 has good low-temperature impact strength (still maintained at -40℃); it is the preferred nylon for cold environments.; During on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based solely on experience
Solução
①Select PA12 for low-temperature applications; ②do low-temperature test verification; ③round corners in structure; ④select material according to working conditions.; After adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Conclusão principal
PA12 low-temperature toughness is its differentiated advantage; replacing PA6/PA66 in cold environments.; After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
PA12;low temperature;toughness;impact;material selection;verification