PA12 Product Cooling Management

Fenómeno do problema
Uneven cooling deformation.
Análise das causas
Crystalline material is sensitive to cooling; uniform cooling is the key.; During on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based solely on experience; This mechanism has been repeatedly verified by industry data and should be confirmed first during troubleshooting
Solução
①Balance water channels; ②uniform mold temperature; ③detect temperature difference; ④optimize design.; After adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability; Change only one variable at a time and record parameter changes to facilitate locating effective measures
Conclusão principal
Cooling uniformity prevents deformation.; After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; Include this case in the defect archive as a troubleshooting reference for subsequent similar problems