Material Analysis 14 visualizações

PA12 Melt Temperature Upper Limit Control

Fenómeno do problema
【Problem phenomenon】To improve filling, the temperature was continuously raised, and PA12 products discolored, lost strength, or even decomposed
Análise das causas
The melt of standard PA12 must not exceed 310℃, and flame-retardant grades must not exceed 270℃; exceeding the upper limit means thermal degradation, manifested as discoloration, bubbles, and decline in mechanical properties
Solução
Set temperature upper limit alarms: 310℃ for standard material, 270℃ for flame-retardant material; for insufficient filling, prioritize adjusting mold temperature and injection speed rather than raising temperature without limit; calibrate the set value with actual melt temperature measurement
Conclusão principal
310℃/270℃ are the double red lines of PA12 temperature, and filling problems should not rely only on raising temperature; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
temperature upper limitflame-retardant gradethermal degradationactual melt temperature measurement