Material Drying 8 visualizações

PA66 water absorption dimensional change

Fenómeno do problema
Products swell in dimension and lose rigidity after moisture absorption, precision assembly fails.
Análise das causas
PA66 equilibrium water absorption at 50%RH is about 2.5%, dimensional change 0.5%~1%; precision fails in hot-humid environments; this is the material nature of PA66.
Solução
①Indicate measurement state on the drawing (dry state/conditioned state); ②measure dimensions after product conditioning stabilizes; ③correct and compensate the mold for wet-state water absorption expansion; ④evaluate low-water-absorption grades such as PA12 for high-humidity precision applications; ⑤do a good job of sealing and moisture-proofing, control environmental and storage humidity.
Conclusão principal
PA66 precision parts 'must define dry/wet state': water absorption expansion is its nature; design by wet state, measure after conditioning, otherwise dimensions will never match; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence.
PA66; water absorption; dimension; conditioning; wet state