Processing Machinery
6 visualizações
PBAT ultraviolet protection
Fenómeno do problema
PBAT outdoor applications undergo ultraviolet aging, and insufficient protection causes rapid performance decline.
Análise das causas
PBAT ultraviolet sensitivity; insufficient anti-UV agent; influence of thickness and color; outdoor environment intensity; service life requirements.; when troubleshooting on site, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience
Solução
①Add anti-UV agent; ②thickness and color design; ③outdoor environment evaluation; ④accelerated aging test.; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Conclusão principal
PBAT outdoor applications must have UV protection; formulation and design are equally important; testing verifies service life.; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
Isto foi útil?
0 pessoas acharam isto útil