Menu
Materiais Máquinas
Perspetivas
Artigos Vídeos Problema e solução
About
Sobre a Chembull Parceiros de média
Contacte-nos
Idioma
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Voltar a Problema e solução
Molds & Tooling 6 visualizações

PBT Hot Runner Forbidden Zone

Fenómeno do problema
After PBT adopts a hot runner, degradation occurs in the manifold, the product is burnt and discolored, and drooling is difficult to control
Análise das causas
Both PBT and PET are not suitable for hot runners: the drooling problem caused by low viscosity is difficult to solve by decompression or temperature adjustment; and PBT easily stays and degrades in the manifold, causing burning and discoloration
Solução
①Avoid using hot runner systems for PBT; ②If it must be used, fully evaluate and demonstrate; ③Make the main runner as short as possible and 0.5-1mm larger than the nozzle; after adjustment, take samples continuously to verify the effect, and resume mass production only after confirming stability
Conclusão principal
The hot runner is a process forbidden zone for PBT; the two major risks of low-viscosity drooling and manifold degradation are superimposed; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
PBT; hot runner; forbidden zone; degradation; drooling

Isto foi útil?

0 pessoas acharam isto útil

ChemAI