Material Analysis
12 visualizações
PC Extruded Sheet Surface Gel Particles
Fenómeno do problema
Tiny bright spots/gel particles appear on the PC sheet surface, failing optical inspection.
Análise das causas
Unplasticized particles, degraded cross-linked matter, or foreign impurities mix into the melt; a broken screen or insufficient mesh count lets impurities through; PC's high-viscosity melt is difficult to plasticize, and unmelted spots are more likely to appear.
Solução
①Increase plasticizing temperature and mixing uniformity; ②Check and replace the screen pack; ③Clean die head dead corners; ④Control the cleanliness of raw material and regrind; ⑤Stabilize the plasticizing process.
Conclusão principal
PC gel particles are first divided into two categories: 'unplasticized and contamination': the former relies on plasticization and screens, the latter on cleaning and dead-corner treatment; optical sheets have extremely high requirements for melt uniformity.