Processing Machinery
6 visualizações
PCABS barrel zone temperature
Fenómeno do problema
【Problem Phenomenon】PC/ABS barrel temperature one-size-fits-all, uneven plasticization or local degradation
Análise das causas
Recommended zoning: rear zone 200-220℃, compression zone 220-240℃, metering zone 240-255℃, nozzle 245-260℃; progressive heating ensures uniform plasticization, nozzle not exceeding 260℃ to prevent degradation
Solução
Set progressively according to the zoning table; nozzle ≤260℃; measure actual melt temperature to calibrate each zone; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability; change only one variable at a time and record the parameter changes, to facilitate locating the effective measures
Conclusão principal
PC/ABS barrel 200 to 260℃ progressive, nozzle 260℃ is the upper limit; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!