Molding Process
7 visualizações
PEEK Bonding and Surface Treatment
Fenómeno do problema
【Problem Phenomenon】PEEK structural bonding strength is insufficient, and the adhesive interface separates
Análise das causas
PEEK has low surface energy and strong chemical inertness, so direct bonding strength is limited; surface pretreatment such as chromic acid etching can significantly improve bonding force; epoxy, polyurethane, and silicone adhesives can all be selected
Solução
Chromic acid etching or plasma treatment of the surface before bonding; select epoxy or silicone system according to service temperature; perform shear strength verification on bonded joints; after adjustment, continuously sample to verify the effect, and resume mass production after confirming stability
Conclusão principal
The success of PEEK bonding lies in surface pretreatment; inert surfaces must be activated; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for similar problems in the future
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!