Material Drying 6 visualizações

PET drying 100 ppm and IV loss

Fenómeno do problema
Products processed from recycled PET become brittle, and the IV value falls below the usable lower limit of 0.70 dL/g
Análise das causas
The PET recycling specification requires drying to below 100 ppm with IV loss <0.04 dL/g; excessive hydrolysis reduces the molecular weight, and impact strength, rigidity, and chemical resistance deteriorate across the board, with the products falling out of the usable range
Solução
①Drying temperature 280-320°F (about 138-160℃) with dew point <-20°F; ②dry pellets for 4 hours and recycled material for 5-6 hours; ③monitor IV loss <0.04 dL/g as the release indicator
Conclusão principal
PET drying quality is quantified by IV loss; the dual indicators of 100 ppm plus 0.04 dL/g are the industry benchmark for recycled PET quality control; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence