Molds & Tooling 7 visualizações

PPS Check Valve and Retention

Fenómeno do problema
Metering fluctuates, part weight is unstable, and cold material spots occasionally appear at the nozzle
Análise das causas
PPS melt viscosity is relatively low; check valve failure causes melt backflow and inaccurate metering; cold material from the nozzle section enters the cavity forming cold material spots; regular inspection of the check valve is the safeguard
Solução
①Regularly inspect the sealing function of the check valve; ②Control nozzle temperature independently to prevent cold material; ③Include metering fluctuation in equipment inspection items; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
Conclusão principal
The low viscosity of PPS amplifies the impact of check valve failure; behind metering stability lies valve health; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence