Processing Machinery 6 visualizações

PPS Radiation Resistance Applications

Fenómeno do problema
Nuclear power plant and medical equipment parts require radiation resistance, and most engineering plastics do not meet the standard
Análise das causas
PPS has excellent resistance to gamma rays and neutron radiation, and is one of the few engineering plastics that can be used long-term in radiation environments; special applications in the nuclear industry and radiological medical equipment
Solução
①Prioritize PPS for radiation environment parts; ②Conduct life verification according to radiation dose; ③Further optimize with radiation-resistant fillers; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
Conclusão principal
Radiation resistance is PPS's differentiated advantage; it is almost irreplaceable in nuclear and medical radiation scenarios; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence