Molding Process 3 visualizações

PVDF Temperature Upper Limit and Thermal Deformation

Fenómeno do problema
【Problem phenomenon】PVDF pipe fittings deform and creep during long-term use at conditions approaching 140-150℃, and pressure-bearing capacity declines
Análise das causas
PVDF's long-term use temperature upper limit is about 140-150℃; near the upper limit, creep accelerates and pressure-bearing capacity declines; overtemperature selection or condition fluctuations beyond the limit lead to early failure
Solução
Design by checking the pipe supplier's long-term strength curve against actual working temperature and pressure; switch to PFA or metal lining for conditions near the upper limit; monitor temperature during operation to prevent exceeding the limit; After adjustment, take consecutive samples to verify the effect, and resume mass production only after confirming stability
Conclusão principal
140-150℃ is PVDF's service ceiling; near the upper limit, material change or derating is required; After confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
temperature upper limitcreeppressure bearingderating