TPE Melt Actual Measurement

Fenómeno do problema
The same set temperature gives different batch quality
Análise das causas
The actual melt temperature deviates from the setting; during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based solely on experience; this mechanism has been repeatedly verified by industry information and should be confirmed first during troubleshooting
Solução
Regularly measure the actual melt temperature; correct the setting with the actual measurement; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability; change only one variable at a time and record parameter changes to facilitate locating effective measures
Conclusão principal
TPE takes the actually measured melt temperature as the benchmark; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a reference for troubleshooting similar problems in the future
TPE melt actual measurement correction benchmark