Extrusion & Post
13 visualizações
Large EVOH Dimensional Change with Temperature
Fenómeno do problema
EVOH product dimensions change >2% over the -20 to 60°C range
Análise das causas
EVOH coefficient of thermal expansion large; crystallinity too low causing high dimensional temperature sensitivity; no annealing, residual stress present
Solução
1) Add rigid filler to lower coefficient of thermal expansion; 2) Annealing to stabilize dimensions; 3) Select high crystallinity grade to reduce temperature sensitivity
Conclusão principal
Dimensional temperature sensitivity is caused by large coefficient of thermal expansion; adding filler and annealing are key
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!