CEF injection multi-cavity filling unbalanced
Fenómeno do problema
The filling amount of each cavity of the CEF injection 8-cavity mold differs by ±15%, some cavities have short shot and some have flash
Análise das causas
The runner design is unbalanced, the runner length and resistance of each cavity are inconsistent; the gate size of each cavity is inconsistent
Solução
1) Adopt a balanced runner design to ensure equal length and equal resistance of each cavity runner; 2) The gate size of each cavity is precisely consistent ±0.01mm; 3) Reduce the injection speed to reduce the influence of resistance differences; 4) Use mold flow analysis software to optimize the runner design
Conclusão principal
Multi-cavity filling imbalance is caused by the runner design; balanced runners and mold flow analysis are the key