Molding Process
3 visualizações
CEF antistatic effect poor
Fenómeno do problema
The surface resistance of the CEF product is >10¹²Ω and the static electricity is severe
Análise das causas
The amount of antistatic agent added is insufficient <0.1wt%; the migration rate of the antistatic agent is slow and does not reach the surface
Solução
1) Increase the antistatic agent to 0.3-0.5wt%; 2) Select an antistatic agent with a fast migration rate; 3) Coat the surface with antistatic liquid for immediate effect
Conclusão principal
Poor antistatic effect is caused by insufficient addition; increasing the antistatic agent is the key
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!