Molding Process
3 visualizações
Glass Fibre extruded pipe sizing sleeve material sticking
Fenómeno do problema
Glass Fibre extruded pipe adheres in sizing sleeve, longitudinal adhesion marks appear on inner wall
Análise das causas
Glass Fibre soft and easily adheres to metal surface; sizing sleeve inner wall rough Ra>0.4μm; sizing sleeve insufficient cooling, surface temperature too high promotes adhesion
Solução
1) Polish sizing sleeve inner wall to Ra<0.2μm; 2) sizing sleeve fully water-cooled, surface <30°C; 3) pass lubricating water containing 0.1% silicone oil emulsion inside sizing sleeve; 4) apply thin layer on pipe surface to reduce adhesion
Conclusão principal
Sizing sleeve material sticking is caused by elastomer adhesion characteristics; polishing and lubricating water are key
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!