Extrusion & Post
13 visualizações
Solution for flame-retardant formulation of calcium-zinc stabilizer in profile extrusion
Fenómeno do problema
The calcium-zinc PVC system shows flame-retardant formulation-related abnormalities in the profile extrusion production stage, customers complain.
Análise das causas
The precipitation characteristic of calcium-zinc stabilizers produces flame-retardant formulation problems under specific working conditions.
Solução
From the formulation perspective, adjust the calcium-zinc metal ratio, combined with process optimization to solve it.
Conclusão principal
The flame-retardant formulation problem of the calcium-zinc system in the profile extrusion stage requires bidirectional adjustment of formulation and process.