Material Analysis
14 visualizações
Analysis and solution of degradation color difference of High-temp MB in PA medical parts
Fenómeno do problema
High-temp MB shows abnormal performance related to degradation color difference when producing medical parts with PA.
Análise das causas
The main cause is parameters not strictly controlled in terms of degradation color difference leading to unstable processing.
Solução
Comprehensively solve the degradation color difference problem from the perspective of formulation optimization.
Conclusão principal
Control of degradation color difference of High-temp MB is the key link to ensure processing quality.
Isto foi útil?
0 pessoas acharam isto útil