Material Drying 7 visualizações

Control of demolding abnormality in PEOX blown film medical products

Fenómeno do problema
During PEOX blown film production of medical products, the problem of unstable demolding occurs.
Análise das causas
Mainly due to the processing temperature deviating from the window +70-90°C, moisture content >0.3% exceeding the standard, and shear heat accumulation.
Solução
Strictly control the temperature within the recommended range, fully dry the material to moisture content <0.1%, and strengthen cooling.
Conclusão principal
PEOX processing requires precise control of the three elements of temperature, humidity, and residence time.