Decreased cooling system efficiency of heat-resistant polyethylene extruder (Variant: strengthened measures)

Fenómeno do problema
The product is insufficiently cooled, and the temperature is still high after leaving the cooling water tank, affecting the sizing effect and subsequent cutting. Decreased cooling efficiency leads to reduced production speed or product deformation. Especially on the original basis, additional attention is needed, and this problem is more prominent and requires key attention.
Análise das causas
(1) Cooling water flow insufficient or water pressure low (2) Cooling water temperature too high (3) Cooling water circuit scaled and clogged (4) Cooling water tank length insufficient (5) Product wall thickness large, heat dissipation slow (6) On the original basis, additional attention is needed: process parameter fluctuations or equipment state changes aggravate this problem
Solução
(1) Check the cooling water pump and pipes to ensure sufficient flow and water pressure (2) Add a cooling water temperature reduction device (chiller), control water temperature at 15-25°C (3) Regularly clean the cooling water circuit and cooling water tank to remove scale (4) Increase cooling water tank length or add cooling stations (5) Appropriately reduce extrusion speed for thick-walled products to extend cooling time (6) And strengthen process monitoring; on the original basis, additional attention is needed, paying special attention to parameter stability
Conclusão principal
Decreased cooling efficiency is caused by insufficient water volume or too high water temperature, and the cooling system needs to be improved and water temperature controlled. Targeted preventive measures need to be taken in different production scenarios.