Menu
Materiais Máquinas
Perspetivas
Artigos Vídeos Problema e solução
About
Sobre a Chembull Parceiros de média
Contacte-nos
Idioma
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Voltar a Problema e solução
Extrusion & Post 14 visualizações

Excessive Shrinkage of Polypropylene Extruded Products

Fenómeno do problema
The dimensions of the extruded product shrink significantly after cooling, exceeding the tolerance range. Excessive shrinkage causes the product dimensions to be too small, affecting fitting and use.
Análise das causas
(1) Polypropylene has high crystallinity, and cooling crystallization causes volume shrinkage (2) The melt temperature is too high, the volume expansion is large, and the shrinkage after cooling is large (3) The cooling rate is slow, the crystallinity is high, and the shrinkage is large (4) The haul-off speed is too slow, and the product expands at the die (5) The raw material grade is selected improperly, and the shrinkage is too large
Solução
(1) Appropriately reduce the barrel temperature to the lower value within the range of 200-280°C (2) Appropriately accelerate the cooling rate to reduce crystallinity and reduce shrinkage (3) Adjust the haul-off speed and appropriately increase the stretch ratio (4) Select a grade with small shrinkage, with a shrinkage of 1.0-2.5 (5) Reserve a shrinkage allowance during mold design
Conclusão principal
Excessive shrinkage is caused by high crystallinity or high temperature, and needs to be solved by controlling the temperature and cooling rate.
shrinkagecrystallinitymelt temperaturecooling ratehaul-off speed