Material Drying
7 visualizações
Moisture regain in PET drying hopper
Fenómeno do problema
PET pellets quickly absorb moisture and regain humidity after being discharged from the drying hopper, and the drying effect is lost.
Análise das causas
Dried material is exposed to air for too long (>30min); the connecting pipe from the hopper to the barrel is not sealed; ambient humidity is high.
Solução
Shorten exposure time to <15min; use sealed insulated conveying pipes; control workshop humidity <40%RH.
Conclusão principal
Moisture regain prevention management after PET drying is an important link in ensuring processing quality.
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!