Molding Process 7 visualizações

PETG deformation in high-temperature sterilization

Fenómeno do problema
PETG products deform severely in high-temperature steam sterilization at 121°C or in hot water.
Análise das causas
The PETG heat deflection temperature is about 70-80°C, far below the sterilization temperature, and the low crystallinity cannot withstand high temperature.
Solução
Switch to a heat-resistant copolyester such as Tritan; PETG is only suitable for low-temperature sterilization (ethylene oxide, etc.); mark the use temperature limit.
Conclusão principal
PETG is not suitable for high-temperature steam sterilization.