Material Analysis
14 visualizações
Scattered PLA heat distortion temperature test values
Fenómeno do problema
The HDT test values of PLA products with the same formulation are widely scattered.
Análise das causas
Uneven crystallinity leads to HDT differences, and the test samples have different heat histories.
Solução
Standardize and unify sample preparation and treatment; fully crystallize.
Conclusão principal
The HDT dispersion of PLA is related to the crystallinity difference.
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!