Extrusion & Post 7 visualizações

Uneven surface of methyl styrene-acrylonitrile copolymer extruded pipes

Fenómeno do problema
Uneven surface appears on extruded pipes, affecting product appearance and subsequent processing quality. This problem is common in methyl styrene-acrylonitrile copolymer extrusion production.
Análise das causas
(1) Improper extrusion temperature (220-280°C) setting, unstable melt quality (2) Improper matching of screw rotation speed and haul-off speed (3) Die condition or design problems (4) Improper cooling system settings (5) Raw material quality or pretreatment problems
Solução
(1) Optimize extrusion temperature to a reasonable value within the 220-280°C range (2) Stabilize screw rotation speed and haul-off speed (3) Check die condition, clean accumulated material or repair damage (4) Adjust cooling water temperature and flow (5) Ensure raw material is dried (80-90°C, 2-4h) and clean
Conclusão principal
Extrusion surface defects need to be controlled from three aspects: temperature, speed, and die condition.
uneven surfacepipemethyl styrene-acrylonitrile copolymerextrusion moldingsurface quality