Molds & Tooling 8 görüntüleme

ASA mold temperature upper limit surface

Sorun Belirtisi
ASA mold temperature 40-80°C, upper limit obtains the best surface, but cycle and deformation balance.
Neden Analizi
ASA mold temperature 40-80°C; running at the upper limit obtains the best surface finish; but high temperature extends the cycle; deformation risk; independent temperature control compensation of front and rear molds; surface and efficiency balance.
Çözüm
①Mold temperature 40-80°C control; ②upper limit for high-gloss parts; ③independent temperature control of front and rear molds; ④cycle optimization; ⑤deformation monitoring.; After adjustment, continuously sample to verify the effect, and resume mass production after confirming stability
Temel Çıkarım
ASA mold temperature upper limit is the surface quality key; independent temperature control is the deformation countermeasure; balance is the optimization goal.; After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence