Molds & Tooling 5 görüntüleme

LCP Dimensional Fluctuation and Batch Instability

Sorun Belirtisi
【Problem Phenomenon】Under the same process, key dimensions of LCP products fluctuate between batches, and the variation trends of flow-direction and transverse dimensions are inconsistent
Neden Analizi
Metering backflow, mold temperature fluctuation and crystallization rate differences jointly cause dimensional drift; LCP shrinkage is extremely small, so any process fluctuation is amplified on precision dimensions; Celanese troubleshooting lists a special item on dimensional fluctuation and associates it with the check ring and mold temperature
Çözüm
First measure check ring backflow to rule out metering problems; raise the temperature control accuracy of the mold temperature controller to within ±2℃; fix the holding switchover point and back pressure, and establish SPC monitoring of key dimensions
Temel Çıkarım
LCP's low shrinkage amplifies process fluctuations; metering and mold temperature stability are the keys to dimensions; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
dimensional fluctuation check ring mold temperature accuracy SPC