Molds & Tooling 5 görüntüleme

PP Delayed Deformation Post-Crystallization

Sorun Belirtisi
【Problem Phenomenon】PP products continue to deform during storage after demolding
Neden Analizi
PP post-crystallization: crystallization continues after demolding, dimensional shrinkage changes over time; high temperature environment accelerates it; this is a characteristic of semi-crystalline materials; during on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based only on experience
Çözüm
Sufficient cooling and shaping; annealing stabilization for high-temperature use parts; consider aging in dimensional measurement; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability; change only one variable at a time and record parameter changes to facilitate locating effective measures
Temel Çıkarım
PP post-crystallization causes delayed deformation, sufficient cooling and annealing stabilize; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for similar problems in the future
post-crystallizationdeformationannealingaging