Production & Quality 12 görüntüleme

Poor EAA fatigue resistance

Sorun Belirtisi
EAA product fatigue life <10⁴ cycles below the 10⁵ cycle requirement
Neden Analizi
EAA elastic recovery insufficient, plastic deformation accumulating with each cycle; crosslinking degree too low, fatigue crack propagation fast
Çözüm
1) Increase crosslinking degree to improve recovery and reduce accumulated deformation; 2) Select high molecular weight grade to raise the fatigue threshold; 3) Product design to reduce stress concentration
Temel Çıkarım
Poor fatigue resistance is caused by insufficient recovery and fast crack propagation; increasing crosslinking is key
EAAfatigue resistancecrosslinking degreemolecular weightstress concentration