Menü
Malzemeler Makineler
İçgörüler
Makaleler Videolar Sorun ve Çözüm
About
Chembull Hakkında Medya Ortakları
Bize Ulaşın
Dil
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Sorun ve Çözüme Geri Dön
Molding Process 8 görüntüleme

Poor EAA antistatic effect

Sorun Belirtisi
EAA product surface resistance >10¹²Ω, severe static electricity
Neden Analizi
Insufficient antistatic agent addition <0.1wt%; antistatic agent migration rate slow, not reaching the surface
Çözüm
1) Increase antistatic agent to 0.3-0.5wt%; 2) Select an antistatic agent with fast migration rate; 3) Coat the surface with antistatic liquid for immediate effect
Temel Çıkarım
Poor antistatic effect is caused by insufficient addition amount; increasing antistatic agent is key
EAAantistaticantistatic agentsurface resistancemigration rate

Bu faydalı oldu mu?

0 kişi bunu faydalı buldu

ChemAI