Molding Process
3 visualizações
Poor EAA antistatic effect
Fenómeno do problema
EAA product surface resistance >10¹²Ω, severe static electricity
Análise das causas
Insufficient antistatic agent addition <0.1wt%; antistatic agent migration rate slow, not reaching the surface
Solução
1) Increase antistatic agent to 0.3-0.5wt%; 2) Select an antistatic agent with fast migration rate; 3) Coat the surface with antistatic liquid for immediate effect
Conclusão principal
Poor antistatic effect is caused by insufficient addition amount; increasing antistatic agent is key
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!