Menü
Malzemeler Makineler
İçgörüler
Makaleler Videolar Sorun ve Çözüm
About
Chembull Hakkında Medya Ortakları
Bize Ulaşın
Dil
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Sorun ve Çözüme Geri Dön
Injection Molding 6 görüntüleme

EMA Injection Gate Freezes Too Early

Sorun Belirtisi
The gate of EMA injection molded products freezes within 0.5-1s during the holding stage, holding pressure cannot be transmitted, product shrinkage severe
Neden Analizi
Gate size too small, diameter <1mm, causing rapid freezing; injection temperature low; mold temperature low, accelerating gate cooling
Çözüm
1) Increase gate diameter to 1.5-2mm; 2) Increase injection temperature to 160-210°C; 3) Increase mold temperature to 40-50°C to delay gate freezing; 4) Holding pressure decays in steps rather than sudden release
Temel Çıkarım
Premature gate freezing is caused by small gate and low temperature; enlarging the gate and increasing temperature are fundamental measures
EMA injection gate freezing holding pressure transmission gate size mold temperature

Bu faydalı oldu mu?

0 kişi bunu faydalı buldu

ChemAI