Injection Molding 4 görüntüleme

EMA '2079851475616104452 Flow Marks

Sorun Belirtisi
Radial flow marks centered on the gate appear on the surface of EMA injection molded products
Neden Analizi
Injection speed too fast, causing melt front instability; mold temperature too low <30°C, front cools rapidly forming marks
Çözüm
1) Adopt multi-stage injection speed slow-fast-slow to control front stability; 2) Increase mold temperature to 40-50°C to delay front cooling; 3) Stabilize injection pressure to avoid fluctuation; 4) Enlarge gate area to reduce sudden pressure change at the gate
Temel Çıkarım
Flow marks are caused by unstable injection front and rapid cooling; multi-stage injection and high mold temperature are key
EMA injection flow marks injection speed mold temperature gate area