Extrusion & Post 11 görüntüleme

EMA Extruded Pipe Ovality Out of Standard

Sorun Belirtisi
EMA extruded pipe ovality >1.05, exceeding the 1.02 standard requirement
Neden Analizi
Pipe cooling uneven, single-side cooling; sizing sleeve design unreasonable; haul-off clamping force uneven, causing the pipe to deform under pressure
Çözüm
1) Adopt annular spray cooling to ensure uniform temperature reduction; 2) Optimize the sizing sleeve inner diameter and taper design; 3) Multi-caterpillar uniform clamping haul-off; 4) Increase the vacuum sizing section length to ensure full sizing
Temel Çıkarım
Ovality is caused by uneven cooling and clamping; annular cooling and uniform haul-off are key
EMA pipe ovality annular cooling vacuum sizing uniform haul-off